Ionizing Smoke Detectors Containing Radioactive Americium 241 Are Deadly Dangerous!

مواضيع مفضلة

Ionizing Smoke Detectors Containing Radioactive Americium 241 Are Deadly Dangerous!

This video explains how ionizing smoke detectors are deadly dangerous for a wide variety of reasons.. well worth listening to. 

DETECTOR MEASURES 120 CPM OUTSIDE OF SMOKE DETECTOR





This video shows the 120 peak CPM radioactivity that can be measured as it comes from an ionization-type smoke detector that contains 0.9 microcuries of radioactive Americium 241 (according to the label). A simple Geiger counter with a pancake probe is used for the measurements. 



Theoretically, alpha radiation coming from Americium cannot penetrate through a sheet of paper, but here it is inside of a metal box, which is then inside of a plastic box, along with a layer of air sandwiched between them. All of these things should be blocking 100% of all alpha radiation, correct? What is actually being measured are gamma rays, which make up a tiny 1% of the radiation coming from Americium. So if the shroud and plastic cover is removed, the alpha radiation levels will skyrocket up and be very hazardous. 

If you look at other YouTube videos, you can see that the tiny americium source is intensely radioactive -- perhaps even too radioactive to be measured with this type of Geiger counter, since it would overwhelm the Geiger tube. Only a tiny fraction of that radioactivity passes through the case and escapes from the smoke detector.

DO NOT DISASSEMBLE AN IONIZING SMOKE DETECTOR! 


Do not disassemble the smoke detector, since the radioactive sample inside of it is extremely hazardous via inhalation of the radioactive particles, or by touching the sample, which is then transferred by hand to various objects, the face, mouth, eyes, etc. 


This video demonstrates something you should warn your kids about, and teach them to NEVER attempt what this kid is doing. Why not? Alpha radiation is deadly when inhaled. Disturbing this small chip of Americium can liberate particles that can be inhaled and then cause lung cancer, or any number of other diseases, as the alpha particle travels through the body.

Alpha Radiation Dangers; Americium, Polonium, Radon, Radium, Plutonium, Uranium; via@AGreenRoad

http://agreenroad.blogspot.com/2012/04/alpha-radiation-dangers-polonium-radon.html

EXPERIMENT WITH LIVING PLANTS NEAR SMOKE DETECTORS




The best strategy if you are concerned about having multiple radioactive sources emitting radiation into the house is to just replace all smoke detectors in the house with a photoelectric type that do not use any deadly radioactive element that will tempt kids to do VERY stupid things like this kid did. 


The above video shows how dangerous radiation based smoke detectors may be to all living things. Remember that kids are 2,000 times more sensitive to radiation than adults are. More experiments are needed to confirm this result. 


He found this monocot that appears to react to radiation, but it is not the only plant that may be very sensitive to radiation. Spiderworts are known to also be highly sensitive to radiation- picking it up at lower levels than scientific instruments. 

Within a couple weeks of being exposed to radiation, the flowers mutate, and turn from violet blue to a bright pink. Obviously, some plants are more immune to negative radiation effects, and different plants will be affected in different ways, just like people. 


If you do an experiment with plants and ionizing radiation detectors, send us an email and we will post it.  agreenroad at gmail.com  . For more information about the effects of low dose radiation on plants, click on the following;



Animals, Insects, Birds And Plants; Low Level Radiation Effects
http://agreenroad.blogspot.com/p/animals-and-low-level-radiation-effects.html


While you are at it, you may want to buy a radon detector at your local hardware store, and check your house for radon, because radon gas has been proven to cause lung cancer. Radon, just like all of the other radioactive elements, is invisible, odorless, and tasteless.

SMOKE DETECTORS WORK LIKE THIS


According to wikipedia; smoke detectors work like this..."


A video overview of how a smoke detector works.
Smoke Detector COFEM with approved EN 54-7.

A smoke detector also called a smoke alarm is a device that detects smoke, typically as an indicator of fire. Commercial, industrial, and mass residential devices issue a signal to a fire alarm system, while household detectors, known as smoke alarms, generally issue a local audible or visual alarm from the detector itself.

Smoke detectors are typically housed in a disk-shaped plastic enclosure about 150 millimetres (6 in) in diameter and 25 millimetres (1 in) thick, but the shape can vary by manufacturer or product line. Most smoke detectors work either by optical detection (photoelectric) or by physical process (ionization), while others use both detection methods to increase sensitivity to smoke.

Sensitive alarms can be used to detect, and thus deter, smoking in areas where it is banned such as toilets and schools. Smoke detectors in large commercial, industrial, and residential buildings are usually powered by a central fire alarm system, which is powered by the building power with a battery backup. However, in many single family detached and smaller multiple family housings, a smoke alarm is often powered only by a single disposable battery.

In the United States, the National Fire Protection Association estimates that nearly two-thirds of deaths from home fires occur in properties without working smoke alarms/detectors.[1]

History


The first automatic electric fire alarm was invented in 1890 by Francis Robbins Upton (U.S. patent no. 436,961). Upton was an associate of Thomas Edison.

George Andrew Darby patented the first electrical heat detector and smoke detector in 1902 in Birmingham, England.[2]

In the late 1930s the Swiss physicist Walter Jaeger tried to invent a sensor for poison gas. He expected that gas entering the sensor would bind to ionized air molecules and thereby alter an electric current in a circuit in the instrument.

His device failed: small concentrations of gas had no effect on the sensor's conductivity. Frustrated, Jaeger lit a cigarette—and was soon surprised to notice that a meter on the instrument had registered a drop in current. Smoke particles had apparently done what poison gas could not. Jaeger's experiment was one of the advances that paved the way for the modern smoke detector.

It was 30 years, however, before progress in nuclear chemistry and solid-state electronics made a cheap sensor possible. While home smoke detectors were available during most of the 1960s, the price of these devices was rather high. Before that, alarms were so expensive that only major businesses and theaters could afford them.

The first truly affordable home smoke detector was invented by Duane D. Pearsall in 1965, featuring an individual battery powered unit that could be easily installed and replaced. The first units for mass production came from Duane Pearsall’s company, Statitrol Corporation, in Lakewood, Colorado. These first units were made from strong fire resistant steel and shaped much like a bee's hive.

OPTICAL SMOKE DETECTOR, NO RADIATION


The need for a quick replace battery didn't take long to show itself and the rechargeable was replaced with a pair of AA batteries along with a plastic shell encasing the detector. The small assembly line sent close to 500 units per day before Statitrol sold its invention to Emerson Electric in 1980 and Sears’s retailers picked up full distribution of the 'now required in every home' smoke detector.
Design[edit]
Optical[edit]
Optical Smoke Detector with the cover removed.
Optical Smoke Detector
1: Optical chamber
2: Cover
3: Case moulding
4: Photodiode (detector)
5: Infrared LED
Inside a basic ionization smoke detector. The black, round structure at the right is the ionization chamber. The white, round structure at the upper left is the piezoelectric buzzer that produces the alarm sound.

Smoke detectors are typically housed in a disk-shaped plastic enclosure about 150 millimetres (6 in) in diameter and 25 millimetres (1 in) thick, but the shape can vary by manufacturer or product line. An optical detector is a light sensor. When used as a smoke detector, it includes a light source (incandescent bulb or infrared LED-Light-Emitting Diode), a lens to collimate the light into a beam, and a photodiode or other photoelectric sensor at an angle to the beam as a light detector.

In the absence of smoke, the light passes in front of the detector in a straight line. When smoke enters the optical chamber across the path of the light beam, some light is scattered by the smoke particles, directing it at the sensor and thus triggering the alarm.

Also seen in large rooms, such as a gymnasium or an auditorium, optical beam smoke detectors are devices that detect a projected beam. A wall-mounted unit sends out a beam, which is either received by a separate monitoring device or reflected back via a mirror. When the beam becomes less visible to the "eye" of the sensor, it sends an alarm signal to the fire alarm control panel.

According to the National Fire Protection Association (NFPA), "photoelectric smoke detection is generally more responsive to fires that begin with a long period of smoldering (called smoldering fires)."

Also, studies by Texas A M and the NFPA cited by the City of Palo Alto California state, "Photoelectric alarms react slower to rapidly growing fires than ionization alarms, but laboratory and field tests have shown that photoelectric smoke alarms provide adequate warning for all types of fires and have been shown to be far less likely to be deactivated by occupants."

Although optical alarms are highly effective at detecting smoldering fires and do provide adequate protection from flaming fires, some fire safety experts and the National Fire Protection Association recommend installing what are called combination alarms, which are alarms that either detect both heat and smoke, or use both the ionization and photoelectric/optical processes. Also some combination alarms may include a carbon monoxide detection capability.

Combination ionization/photoelectric smoke alarms are controversial. The World Fire Safety Foundation (WFSF), the International Association of Fire Fighters (IAFF), the Australasian Fire and Emergency Service Authorities Council (AFAC), the Fire Protection Association of Australia and a growing number of fire departments, consumer and fire safety experts around the world do not recommend them.

IONIZING SMOKE ALARMS MAY NOT PROVIDE ENOUGH WARNING IN CASE OF SMOLDERING FIRE


The official positions of the WFSF, the IAFF and AFAC state, "Ionization smoke alarms may not operate in time to alert occupants early enough to escape from smoldering fires." However, stand-alone photoelectric smoke alarms are proven to provide adequate egress time in both the smoldering and flaming stages of fire.[3]

Not all optical or photoelectric detection methods are the same. The type and sensitivity of the photodiode or optical sensor, and type of smoke chamber differ between manufacturers.
Ionization
An Americium container from a smoke detector.

An ionization smoke detector uses a radioisotope such as americium-241 to produce ionization in air; a difference due to smoke is detected and an alarm is generated. Ionization detectors are more sensitive to the flaming stage of fires than optical detectors, while optical detectors are more sensitive to fires in the early smouldering stage.[4]

The radioactive isotope americium-241 in the smoke detector emits ionizing radiation in the form of alpha particles into an ionization chamber (which is open to the air) and a sealed reference chamber. The air molecules in the chamber become ionized and these ions allow the passage of a small electric current between charged electrodes placed in the chamber.

If any smoke particles pass into the chamber the ions will attach to the particles and so will be less able to carry the current. An electronic circuit detects the current drop, and sounds the alarm. The reference chamber cancels effects due to air pressure, temperature, or the aging of the source.[5]

Other parts of the circuitry monitor the battery (where used) and sound an intermittent warning when the battery nears exhaustion. A self-test circuit simulates an imbalance in the ionization chamber and verifies the function of power supply, electronics, and alarm device.

The standby power draw of an ionization smoke detector is so low that a small battery can provide power for months or years, making the unit independent of AC power supply or external wiring; however, batteries require regular test and replacement.

IONIZING ALARM PRONE TO FALSE ALARMS


An ionization type smoke detector is generally cheaper to manufacture than an optical smoke detector; however, it is sometimes rejected because it is more prone to false (nuisance) alarms than photoelectric smoke detectors.[6][7] It can detect particles of smoke that are too small to be visible.

Americium-241, an alpha emitter, has a half-life of 432 years. Alpha radiation, as opposed to beta and gamma, is used for two additional reasons: Alpha particles have high ionization, so sufficient air particles will be ionized for the current to exist, and they have low penetrative power, meaning they will be stopped by the plastic of the smoke detector or the air, (unless radioactive particles from the 241Am are inhaled, and then it is deadly dangerous.)

About one percent of the emitted radioactive energy of 241Am is gamma radiation. The amount of elemental americium-241 is small enough to be exempt from the regulations applied to larger sources. It includes about 37 kBq or 1 µCi of radioactive element americium-241 (241Am), corresponding to about 0.3 µg of the isotope.[8][9] This provides sufficient ion current to detect smoke, while producing a very low level of radiation outside the device.

SOME EUROPEAN COUNTRIES HAVE BANNED IONIZING SMOKE DETECTORS


The americium-241 in ionizing smoke detectors poses a potential environmental hazard. Disposal regulations and recommendations for smoke detectors vary from region to region.[10][11] Some European countries have banned the use of domestic ionic smoke alarms.[12]

Radiation data[13]   Type                  Energy  Percentage
Alpha                     5485 keV                  84.5%
Alpha                     5443 keV                  13.0%
Gamma                   59.5 keV                  35.9%
Gamma                   26.3 keV                    2.4%
Gamma                   13.9 keV                  42%



Air-sampling


An air-sampling smoke detector is capable of detecting microscopic particles of smoke. Most air-sampling detectors are aspirating smoke detectors, which work by actively drawing air through a network of small-bore pipes laid out above or below a ceiling in parallel runs covering a protected area.

Small holes drilled into each pipe form a matrix of holes (sampling points), providing an even distribution across the pipe network. Air samples are drawn past a sensitive optical device, often a solid-state laser, tuned to detect the extremely small particles of combustion. Air-sampling detectors may be used to trigger an automatic fire response, such as a gaseous fire suppression system, in high-value or mission-critical areas, such as archives or computer server rooms.

Most air-sampling smoke detection systems are capable of a higher sensitivity than spot type smoke detectors and provide multiple levels of alarm threshold, such as Alert, Action, Fire 1 and Fire 2. Thresholds may be set at levels across a wide range of smoke levels. This provides earlier notification of a developing fire than spot type smoke detection, allowing manual intervention or activation of automatic suppression systems before a fire has developed beyond the smoldering stage, thereby increasing the time available for evacuation and minimizing fire damage.

Carbon monoxide and carbon dioxide detection


Some smoke alarms use a carbon dioxide sensor or Carbon monoxide sensor to detect characteristic products of combustion.[14][15] However, some gas sensors react on levels that are dangerous for humans but not typical for a fire; these are therefore not generally sensitive or fast enough to be used as fire detectors. Other gas sensors are even able to warn about particulate-free fires (e. g. certain alcohol fires).

Performance differences

Photoelectric smoke detectors respond faster (typically 30 minutes or more) to fire in its early, smouldering stage (before it breaks into flame). The smoke from the smouldering stage of a fire is typically made up of large combustion particles — between 0.3 and 10.0 µm. Ionization smoke detectors respond faster (typically 30–60 seconds) in the flaming stage of a fire.

The smoke from the flaming stage of a fire is typically made up of microscopic combustion particles — between 0.01 and 0.3 µm. Also, ionization detectors are weaker in high air-flow environments, and because of this, the photoelectric smoke detector is more reliable for detecting smoke in both the smoldering and flaming stages of a fire.[16]

In June, 2006 the Australasian Fire & Emergency Service Authorities Council, the peak representative body for all Australian and New Zealand Fire Departments published an official report, 'Position on Smoke Alarms in Residential Accommodation'. Clause 3.0 states, "Ionization smoke alarms may not operate in time to alert occupants early enough to escape from smouldering fires." [17]

PHOTOELECTRIC SMOKE ALARMS REDUCES LOSS OF LIFE COMPARED TO IONIZING ALARMS


In August, 2008 the International Association of Fire Fighters (IAFF-300,000+ members throughout the USA and Canada) passed a Resolution recommending the use of photoelectric smoke alarms. The IAFF states that changing to photoelectric alarms, "Will drastically reduce the loss of life among citizens and fire fighters."[18]

In June, 2010 the City of Albany, California enacted photoelectric-only legislation after a unanimous decision by the Albany City Council. This was a catalyst for several other Californian and Ohioan cities to enact legislation requiring photoelectric smoke detectors.[19]

AUSTRALIA FIRE PROTECTION ASSOC. RECOMMENDS PHOTOELECTRIC SMOKE ALARMS


In May, 2011 the Fire Protection Association of Australia's (FPAA) official position on smoke alarms states, "Fire Prevention Association Australia considers that all residential buildings should be fitted with photoelectric smoke alarms...".[20]

In November, 2011 the Northern Territory enacted Australia's first residential photoelectric legislation mandating the use of photoelectric smoke alarms in all new Northern Territory homes.[21]

In December, 2011 the Volunteer Fire Fighter's Association of Australia published a World Fire Safety Foundation report, 'Ionization Smoke Alarms are DEADLY", citing research outlining substantial performance differences between ionization and photoelectric technology.[22]

In June, 2013 in an Australian Parliamentary speech, the question was asked, "Are ionization smoke alarms defective?" This was further to the Australian Government's scientific testing agency (the Commonwealth Scientific and Industrial Research Organisation - CSIRO) data revealing serious performance problems with ionization technology in the early, smoldering stage of fire, a rise in litigation involving ionization smoke alarms, and increasing legislation mandating the installation of photoelectric smoke alarms.

The speech cited a May 2013, World Fire Safety Foundation report published in the Australian Volunteer Fire Fighter Association's magazine titled, 'Can Australian and U.S. Smoke Alarm Standards be Trusted?' The speech concluded with a request for one of the world's largest ionization smoke alarm manufacturers and the CSIRO to disclose the level of visible smoke the manufacturers' ionization smoke alarms activate under CSIRO scientific testing.[23]

According to fire tests conformant to EN 54, the CO2 cloud from open fire can usually be detected before particulate.[15]

Due to the varying levels of detection capabilities between detector types, manufacturers have designed multi-criteria devices which cross-reference the separate signals to both rule out false alarms and improve response times to real fires.[16] Examples include Photo/heat, photo/CO, and even CO/photo/heat/IR.

Obscuration is a unit of measurement that has become the standard definition of smoke detector sensitivity. Obscuration is the effect that smoke has on reducing sensor visibility; higher concentrations of smoke result in higher obscuration levels.

Typical smoke detector obscuration ratings[24]

Type of Detector    Obscuration Level

Ionization 2.6–5.0% obs/m (0.8–1.5% obs/ft)
Photoelectric 6.5–13.0% obs/m (2–4% obs/ft)
Beam 3% obs/m (0.9% obs/ft)[citation needed]
Aspirating 0.005–20.5% obs/m (0.0015–6.25% obs/ft)
Laser 0.06–6.41% obs/m (0.02–2.0% obs/ft)[25]

Commercial smoke detectors



An integrated locking mechanism for commercial building doors. Inside an enclosure are a locking device, smoke detector and power supply.

Commercial smoke detectors are either conventional or analog addressable, and are wired up to security monitoring systems or fire alarm control panels (FACP). These are the most common type of detector, and usually cost a lot more than a household smoke alarms.

They exist in most commercial and industrial facilities, such as high rises, ships and trains. These detectors don't need to have built in alarms, as alarm systems can be controlled by the connected FACP, which will set off relevant alarms, and can also implement complex functions such as a staged evacuation.

Conventional


The word "conventional" is slang used to distinguish the method used to communicate with the control unit from that used by addressable detectors whose methods were unconventional at the time of their introduction. So called “Conventional Detectors” cannot be individually identified by the control unit and resemble an electrical switch in their information capacity.

These detectors are connected in parallel to the signaling path or (initiating device circuit) so that the current flow is monitored to indicate a closure of the circuit path by any connected detector when smoke or other similar environmental stimulus sufficiently influences any detector. The resulting increase in current flow is interpreted and processed by the control unit as a confirmation of the presence of smoke and a fire alarm signal is generated.

Addressable

An addressable Simplex smoke detector

This type of installation gives each detector on a system an individual number, or address. Thus, addressable detectors allow an FACP, and therefore fire fighters, to know the exact location of an alarm where the address is indicated on a diagram.

Analog addressable detectors provide information about the amount of smoke in their detection area, so that the FACP can decide itself, if there is an alarm condition in that area (possibly considering day/night time and the readings of surrounding areas). These are usually more expensive than autonomous deciding detectors.[26]

Single Station Smoke Alarms


The main function of a single station or "standalone" smoke alarm is to alert persons at risk. Several methods are used and documented in industry specifications published by Underwriters Laboratories[27] Alerting methods include:

Audible tones
Usually around 3200 Hz due to component constraints (Audio advancements for persons with hearing impairments have been made; see External links)
85 dBA at 10 feet
Spoken voice alert
177 candela output
Tactile stimulation, e.g., bed or pillow shaker (No standards exist as of 2008 for tactile stimulation alarm devices.)

Some models have a hush or temporary silence feature that allows silencing without removing the battery. This is especially useful in locations where false alarms can be relatively common (e.g. due to "toast burning") or users could remove the battery permanently to avoid the annoyance of false alarms, but removing the battery permanently is strongly discouraged.

While current technology is very effective at detecting smoke and fire conditions, the deaf and hard of hearing community has raised concerns about the effectiveness of the alerting function in awakening sleeping individuals in certain high-risk groups such as the elderly, those with hearing loss and those who are intoxicated.[28]

Between 2005 and 2007, research sponsored by the United States' National Fire Protection Association (NFPA) has focused on understanding the cause of a higher number of deaths seen in such high-risk groups. Initial research into the effectiveness of the various alerting methods is sparse.

Research findings suggest that a low frequency (520 Hz) square wave output is significantly more effective at awakening high risk individuals. Wireless smoke and carbon monoxide detectors linked to alert mechanisms such as vibrating pillow pads for the hearing impaired, strobes, and remote warning handsets are more effective at waking people with serious hearing loss than other alarms.[29]

Batteries

Photoelectric smoke detector equipped with strobe light for the hearing impaired

Most residential smoke detectors run on 9-volt alkaline or carbon-zinc batteries. When these batteries run down, the smoke detector becomes inactive. Most smoke detectors will signal a low-battery condition. The alarm may chirp at intervals if the battery is low, though if there is more than one unit within earshot, it can be hard to locate.

REPLACE BATTERIES EVERY YEAR ON APRIL FOOLS DAY


It is common, however, for houses to have smoke detectors with dead batteries. It is estimated, in the UK, that over 30% of smoke alarms may have dead or removed batteries. As a result, public information campaigns have been created to remind people to change smoke detector batteries regularly. In Australia, for example, a public information campaign suggests that smoke alarm batteries should be replaced on April Fools' Day every year.[30] In regions using daylight saving time, campaigns may suggest that people change their batteries when they change their clocks or on a birthday.

Some detectors are also being sold with a lithium battery that can run for about 7 to 10 years, though this might actually make it less likely for people to change batteries, since their replacement is needed so infrequently. By that time, the whole detector may need to be replaced. Though relatively expensive, user-replaceable 9-volt lithium batteries are also available.

Common NiMH and NiCd rechargeable batteries have a high self-discharge rate, making them unsuitable for use in smoke detectors. This is true even though they may provide much more power than alkaline batteries if used soon after charging, such as in a portable stereo.

Also, a problem with rechargeable batteries is a rapid voltage drop at the end of their useful charge. This is of concern in devices such as smoke detectors, since the battery may transition from "charged" to "dead" so quickly that the low-battery warning period from the detector is either so brief as to go unnoticed, or may not occur at all.

The NFPA, recommends that home-owners replace smoke detector batteries with a new battery at least once per year, when it starts chirping (a signal that its charge is low), or when it fails a test, which the NFPA recommends to be carried out at least once per month by pressing the "test" button on the alarm.[31]

Reliability


In 2004, NIST issued a comprehensive report[7] that concludes, among other things, that "smoke alarms of either the ionization type or the photoelectric type consistently provided time for occupants to escape from most residential fires", and "consistent with prior findings, ionization type alarms provided somewhat better response to flaming fires than photoelectric alarms (57 to 62 seconds faster response), and photoelectric alarms provided (often) considerably faster response to smoldering fires than ionization type alarms (47 to 53 minutes faster response)".

REPLACE SMOKE ALARMS EVERY TEN YEARS


The NFPA strongly recommends the replacement of home smoke alarms every 10 years. Smoke alarms become less reliable with time, primarily due to aging of their electronic components, making them susceptible to nuisance false alarms. In ionization type alarms, decay of the 241Am radioactive source is a negligible factor, as its half-life is far greater than the expected useful life of the alarm unit.

Regular cleaning can prevent false alarms caused by the build up of dust or other objects such as flies, particularly on optical type alarms as they are more susceptible to these factors. A vacuum cleaner can be used to clean ionization and optical detectors externally and internally. However, on commercial ionization detectors it is not recommended for a lay person to clean internally. To reduce false alarms caused by cooking fumes, use an optical or 'toast proof' alarm near the kitchen. [32]

LEGAL CASE INVOLVING SMOKE ALARM


A jury in the United States District Court for the Northern District of New York decided in 2006 that First Alert and its parent company, BRK Brands, was liable for millions of dollars in damages because the ionization smoke alarm in the Hackert's house was a defective design by its nature, typically failing to detect the slow-burning fire and choking smoke that filled the home as the family slept.[33]

Installation and placement
A 2007 U.S. guide to placing smoke detectors, suggesting that one be placed on every floor of a building, and in each bedroom.

In the United States, most state and local laws regarding the required number and placement of smoke detectors are based upon standards established in NFPA 72, National Fire Alarm and Signaling Code.

Laws governing the installation of smoke detectors vary depending on the locality. Homeowners with questions or concerns regarding smoke detector placement may contact their local fire marshal or building inspector for assistance.

However, some rules and guidelines for existing homes are relatively consistent throughout the developed world. For example, Canada and Australia require a building to have a working smoke detector on every level. The United States NFPA code cited in the previous paragraph requires smoke detectors on every habitable level and within the vicinity of all bedrooms. Habitable levels include attics that are tall enough to allow access.

In new construction, minimum requirements are typically more stringent. All smoke detectors must be hooked directly to the electrical wiring, be interconnected and have a battery backup. In addition, smoke detectors are required either inside or outside every bedroom, depending on local codes.

Smoke detectors on the outside will detect fires more quickly, assuming the fire does not begin in the bedroom, but the sound of the alarm will be reduced and may not wake some people. Some areas also require smoke detectors in stairways, main hallways and garages.

Wired units with a third "interconnect" wire allow a dozen or more detectors to be connected, so that if one detects smoke, the alarms will sound on all the detectors in the network, improving the chances that occupants will be alerted, even if they are behind closed doors or if the alarm is triggered one or two floors from their location.

Wired interconnection may only be practical for use in new construction, especially if the wire needs to be routed in areas that are inaccessible without cutting open walls and ceilings. As of the mid-2000s, development has begun on wirelessly networking smoke alarms, using technologies such as ZigBee, which will allow interconnected alarms to be easily retrofitted in a building without costly wire installations.

Some wireless systems using Wi-Safe technology will also detect smoke or carbon monoxide through the detectors, which simultaneously alarm themselves with vibrating pads, strobes and remote warning handsets. As these systems are wireless they can easily be transferred from one property to another.

In the UK the placement of detectors is similar however the installation of smoke alarms in new builds need to comply to the British Standards BS5839 pt6. BS 5839: Pt.6: 2004 recommends that a new-build property consisting of no more than 3 floors (less than 200sqm per floor) should be fitted with a Grade D, LD2 system. Building Regulations in England, Wales and Scotland recommend that BS 5839: Pt.6 should be followed, but as a minimum a Grade D, LD3 system should be installed. Building Regulations in Northern Ireland require a Grade D, LD2 system to be installed, with smoke alarms fitted in the escape routes and the main living room and a heat alarm in the kitchen, this standard also requires all detectors to have a main supply and a battery back up.
EN54 European Standard for Smoke Detector[edit]

Fire detection products have the European Standard EN 54 Fire Detection and Fire Alarm Systems that is a mandatory standard for every product that is going to be delivered and installed in any country in the European Union (EU). EN 54 part 7 is the standard for smoke detectors. European standard are developed to allow free movement of goods in the European Union countries. EN 54 is widely recognized around the world. The EN 54 certification of each device must be issued annually.[34] [35]

Smoke Alarm Standards


In June, 2013 a World Fire Safety Foundation report titled, 'Can Australian and U.S. Smoke Alarm Standards be Trusted?' was published in the official magazine of the Australian Volunteer Fire Fighter's Association. The report brings into question the validity of testing criteria used by American and Australian government agencies when undergoing scientific testing of ionization smoke alarms in smoldering fires.[37]"
http://en.wikipedia.org/wiki/Americium_smoke_detector#Ionization


End

Ionizing Smoke Detectors Containing Radioactive Americium 241 Are Deadly Dangerous!  via @AGreenRoad